{"created":"2023-06-19T09:47:22.032961+00:00","id":1843,"links":{},"metadata":{"_buckets":{"deposit":"1dc5d6db-5a1b-4844-8be9-7653a5243a70"},"_deposit":{"created_by":3,"id":"1843","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"1843"},"status":"published"},"_oai":{"id":"oai:keiai.repo.nii.ac.jp:00001843","sets":["1:9:169:171"]},"author_link":["5490","5491"],"item_3_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1989-01-20","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"35","bibliographicPageEnd":"375","bibliographicPageStart":"369","bibliographic_titles":[{"bibliographic_title":"敬愛大学研究論集"},{"bibliographic_title":"KEIAI UNIVERSITY STAFF PAPERS","bibliographic_titleLang":"en"}]}]},"item_3_description_10":{"attribute_name":"抄録(日)","attribute_value_mlt":[{"subitem_description":"発色試薬を用いる微量のユウロピウム(III)イオンの吸光光度定量法を研究した。試料溶液に一定量の発色試薬溶液を加え, 緩衝溶液を加えてpH10.6に調整し, 室温で50分間放置する。赤色に発色した溶液の吸光度を, 579nmで試薬ブランクを対照として測定して定量する。本法により1.0×10^<-7>~1.2×10^<-5>Mの範囲でベールの法則に従い高感度で正確に定量できる。ユウロピウム(III)錯体のモル吸光係数は1.5×10^5で, 5.0×10^<-6>Mの濃度での変動係数は0.4%で, 感度, 再現性共に良好である。","subitem_description_type":"Other"}]},"item_3_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN10065054","subitem_source_identifier_type":"NCID"}]},"item_3_text_6":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"敬愛大学経済学部"}]},"item_3_text_7":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Faculty of Economics,Keiai University"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"友成, 明久"},{"creatorName":"トモナリ, アキヒサ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"5490","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tomonari, Akihisa","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"5491","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-08-18"}],"displaytype":"detail","filename":"KJ00000176304.pdf","filesize":[{"value":"225.4 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"KJ00000176304.pdf","url":"https://keiai.repo.nii.ac.jp/record/1843/files/KJ00000176304.pdf"},"version_id":"464509f7-71d2-45d7-b2fc-55f5b802139e"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"微量ユウロピウム(III)イオンの吸光光度定量法","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"微量ユウロピウム(III)イオンの吸光光度定量法"},{"subitem_title":"Spectrophotometric Determination of Trace Europium (III) Ion","subitem_title_language":"en"}]},"item_type_id":"3","owner":"3","path":["171"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-08-18"},"publish_date":"2016-08-18","publish_status":"0","recid":"1843","relation_version_is_last":true,"title":["微量ユウロピウム(III)イオンの吸光光度定量法"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:39:40.982644+00:00"}